Quicklabel NiceWatch Uživatelský manuál Strana 68

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 86
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 67
Working with Triggers
68
NiceWatch User Guide
To limit connection to your TCP/IP triggers, do the following:
1. Double click your TCP/IP trigger to display its properties.
2. Go to the TCP/IP tab.
3. Click on the button Host Connection Permissions.
The dialog box Host Connect Options opens.
4. Type in the IP addresses of the hosts you do not want to connect to your TCP/IP
server in the text box Deny connection from the following hosts.
The connection requests coming from the entered hosts will be denied.
Note:
You can also enter the IP addresses from the hosts that you trust. Use the text box Allow
connection from the following hosts.
When the middleware integration server executable runs in the service mode, it is started
automatically when the Windows operating system loads. There is no need for any of the
users to log in and manually start the service.
To start the middleware server in the service mode, do the following:
1. Open the middleware integration client.
2. Make sure the server is not running. To stop the server, select the command Stop
Server in the Activities menu.
Note:
To stop the server you can also click on the button in the server toolbar.
3. Select the command Register Service from the Tools menu.
The dialog box Service Preferences will open.
4. For Startup Type select how the middleware server should start as service. You
probably want to select the option Automatic to be sure the server starts
automatically at each restart of the computer.
5. For Log On As select under which user the service should run.
Note:
To run the application under domain user type in the user name in the syntax
<DOMAIN>\<USER NAME>. To run the application under the local user type in the
user name in the syntax .\<USER NAME>. To run the application under a System
Account, select the option System Account.
6. Click on the OK button.
7. Select the command Start Server from the Activities tab.
Zobrazit stránku 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 85 86

Komentáře k této Příručce

Žádné komentáře

Bunn HC-3 manuales

Manuales del propietario y guías del usuario para Dispensador De Agua Bunn HC-3.
Ofrecemos 1 manuales en pdf Bunn HC-3 para descargar gratis por tipos de documentos: Manual de usuario






Más productos y manuales para Dispensador De Agua Bunn

Modelos Tipo de documento
JDF-2 Manual de usuario   Bunn JDF-2 User's Manual, 22 paginas
LCA-2 Manual de usuario   Bunn LCA-2 User's Manual, 26 paginas
ULTRA-1B Manual de servicio   Bunn ULTRA-1B Service manual, 17 paginas
FMD-2 Manual de servicio   Bunn FMD-2 Service manual, 36 paginas
ULTRA-1B Manual de servicio   Bunn ULTRA-1B Service manual, 40 paginas
VP17 Series Manual de servicio   Bunn VP17 Series Service manual, 8 paginas
IMIX Manual de servicio   Bunn IMIX Service manual, 17 paginas
FMD-4 Manual de servicio   Bunn FMD-4 Service manual, 7 paginas
TCD-1 Manual de usuario   TCD-1 TCD-2 - Whaley Food Service, 18 paginas
JDF-4 Guía para resolver problemas   Bunn JDF-4 Troubleshooting guide, 32 paginas
IMIX-5S+ Manual de servicio   Bunn IMIX-5S+ Service manual [en] [es] [fr] , 13 paginas
T6A Manual de servicio   Bunn T6A Service manual, 30 paginas
AF PR-3 Manual de servicio   Bunn AF PR-3 Service manual, 17 paginas
AFPO-3 SL Manual de servicio   Bunn AFPO-3 SL Service manual, 8 paginas
ULTRA Manual de usuario   UNIT 4 PREVENTIVE MAINTENANCE, 3 paginas
FCD-4 Manual de usuario   Installation, Operating, FCD-4 Installation & Operating Manual, 22 paginas
IMIX-5S+ Manual de servicio   Bunn IMIX-5S+ Service manual, 8 paginas
VP17 Series Manual de servicio   Bunn VP17 Series Service manual, 19 paginas
AF PR-3 Manual de usuario   AF PR-2 AF PR-3, 24 paginas
TCD-1 Manual de usuario   TCD-1/2, 18 paginas